{"id":19940,"date":"2026-08-13T09:18:04","date_gmt":"2026-08-13T09:18:04","guid":{"rendered":"https:\/\/sklep.plcexpert.pl\/?post_type=product&#038;p=19940"},"modified":"2026-08-13T10:39:19","modified_gmt":"2026-08-13T10:39:19","slug":"stanowisko-dydaktyczne-plc-czujniki-z-interfejsem-io-link","status":"publish","type":"product","link":"https:\/\/sklep.plcexpert.pl\/en\/product\/stanowisko-dydaktyczne-plc-czujniki-z-interfejsem-io-link\/","title":{"rendered":"PLC training station \u2013 sensors with IO-Link interface"},"content":{"rendered":"<div style=\"    width:100% !important;    max-width:none !important;    margin:0 !important;    padding:0 !important;    box-sizing:border-box;    color:#1f2937;    font-family:Arial, Helvetica, sans-serif;    font-size:16px;    line-height:1.35;\"><\/p>\n<p>    <!-- OPIS OG\u00d3LNY --><\/p>\n<p style=\"        margin:0 0 10px 0;        padding:0;        text-align:left;        font-size:16px;        line-height:1.35;    \"><br \/>\n        Stanowisko edukacyjne przeznaczone do nauki obs\u0142ugi, integracji oraz konfiguracji<br \/>\n        czujnik\u00f3w z cyfrowym interfejsem komunikacyjnym IO-Link, realizowane z wykorzystaniem<br \/>\n        sterownika PLC oraz panelu operatorskiego HMI. Umo\u017cliwia realizacj\u0119 \u0107wicze\u0144 z zakresu<br \/>\n        komunikacji sieciowej, zbierania danych z inteligentnych czujnik\u00f3w, sterowania<br \/>\n        elementami wykonawczymi i diagnostyki procesu.\n    <\/p>\n<p style=\"        margin:0 0 10px 0;        padding:0;        text-align:left;        font-size:16px;        line-height:1.35;    \"><br \/>\n        Kompaktowa konstrukcja dydaktyczna typu \u201eL\u201d wykonana z profili aluminiowych,<br \/>\n        przystosowana do pracy na stole laboratoryjnym. Cz\u0119\u015b\u0107 pozioma zawiera p\u0142yt\u0119<br \/>\n        monta\u017cow\u0105 rowkowan\u0105, cz\u0119\u015b\u0107 pionowa przeznaczona jest na sterownik PLC i panel HMI.<br \/>\n        Konstrukcja wyposa\u017cona jest w uchwyty transportowe, szyny monta\u017cowe DIN oraz<br \/>\n        korytka kablowe.\n    <\/p>\n<p style=\"        margin:0 0 12px 0;        padding:0;        line-height:1.35;    \"><br \/>\n        <strong>Wymiary stanowiska:<\/strong> oko\u0142o 860 x 360 x 630 mm.\n    <\/p>\n<div style=\"        margin:0 0 8px 0;        padding:0;        font-weight:700;    \"><br \/>\n        Wyposa\u017cenie stanowiska:\n    <\/div>\n<p>    <!-- 1 --><\/p>\n<div style=\"margin:0 0 10px 0; padding:0;\">\n        <strong>1. Sterownik PLC:<\/strong><br \/>\n        Jednostka zasilana napi\u0119ciem 24 V DC, wyposa\u017cona w min. 14 wej\u015b\u0107 cyfrowych,<br \/>\n        10 wyj\u015b\u0107 cyfrowych, 2 wej\u015bcia analogowe, 2 wyj\u015bcia analogowe, dostarczany<br \/>\n        z oprogramowaniem narz\u0119dziowym na licencji edukacyjnej.\n    <\/div>\n<p>    <!-- 2 --><\/p>\n<div style=\"margin:0 0 10px 0; padding:0;\">\n        <strong>2. Panel operatorski HMI:<\/strong><br \/>\n        Dotykowy panel o przek\u0105tnej ekranu min. 4&quot;,<br \/>\n        kompatybilny ze sterownikiem PLC.\n    <\/div>\n<p>    <!-- 3 --><\/p>\n<div style=\"margin:0 0 10px 0; padding:0;\">\n        <strong>3. Zasilacz:<\/strong><br \/>\n        Zasilacz stabilizowany o napi\u0119ciu wyj\u015bciowym 24 V DC, min. 2 A.\n    <\/div>\n<p>    <!-- 4 --><\/p>\n<div style=\"margin:0 0 10px 0; padding:0;\">\n        <strong>4. Modu\u0142 bezpiecznego zasilania:<\/strong><br \/>\n        Modu\u0142 zasilaj\u0105cy wyposa\u017cony w gniazdo zasilania 24 V DC,<br \/>\n        gniazdo na bezpiecznik topikowy oraz w\u0142\u0105cznik stanowiska.\n    <\/div>\n<p>    <!-- 5 --><\/p>\n<div style=\"margin:0 0 10px 0; padding:0;\">\n        <strong>5. Sie\u0107 komunikacyjna:<\/strong><br \/>\n        Niezarz\u0105dzalny switch przemys\u0142owy Ethernet, min. 5 port\u00f3w.\n    <\/div>\n<p>    <!-- 6 --><\/p>\n<div style=\"margin:0 0 10px 0; padding:0;\">\n        <strong>6. System IO-Link:<\/strong><br \/>\n        Modu\u0142 typu Master IO-Link obs\u0142uguj\u0105cy min. 4 urz\u0105dzenia IO-Link.\n    <\/div>\n<p>    <!-- 7 --><\/p>\n<div style=\"margin:0 0 12px 0; padding:0;\">\n<div style=\"font-weight:700; margin:0 0 5px 0;\">\n            7. Czujniki IO-Link: Zestaw czujnik\u00f3w inteligentnych:\n        <\/div>\n<ul style=\"            margin:4px 0 0 22px;            padding-left:18px;            line-height:1.35;        \"><\/p>\n<li style=\"margin:0 0 4px 0;\">\n                <strong>Optyczny<\/strong> \u2013 dalmierz laserowy,<br \/>\n                zasi\u0119g dzia\u0142ania min. 1 m.\n            <\/li>\n<li style=\"margin:0 0 4px 0;\">\n                <strong>Ultrad\u017awi\u0119kowy<\/strong> \u2013 zakres dzia\u0142ania min. 300 mm.\n            <\/li>\n<li style=\"margin:0 0 4px 0;\">\n                <strong>Indukcyjny<\/strong> \u2013 zasi\u0119g dzia\u0142ania min. 4 mm.\n            <\/li>\n<li style=\"margin:0;\">\n                <strong>Pojemno\u015bciowy<\/strong> \u2013 zasi\u0119g dzia\u0142ania min. 8 mm.\n            <\/li>\n<\/ul><\/div>\n<p>    <!-- 8 --><\/p>\n<div style=\"margin:0 0 10px 0; padding:0;\">\n        <strong>8. Uk\u0142ad nap\u0119dowy:<\/strong><br \/>\n        Prowadnica liniowa z \u015brub\u0105 kulow\u0105 i silnikiem krokowym<br \/>\n        oraz dedykowanym sterownikiem.\n    <\/div>\n<p>    <!-- 9 --><\/p>\n<div style=\"margin:0 0 10px 0; padding:0;\">\n        <strong>9. Interfejsy:<\/strong><br \/>\n        Interfejs sterownika PLC oraz urz\u0105dze\u0144 wykonawczych.\n    <\/div>\n<p>    <!-- 10 --><\/p>\n<div style=\"margin:0 0 10px 0; padding:0;\">\n        <strong>10. Elementy sterownicze i sygnalizacyjne:<\/strong><br \/>\n        Przyciski sterownicze oraz kontrolki sygnalizacyjne<br \/>\n        zasilane napi\u0119ciem 24 V DC.\n    <\/div>\n<p>    <!-- 11 --><\/p>\n<div style=\"margin:0 0 10px 0; padding:0;\">\n        <strong>11. Elementy uzupe\u0142niaj\u0105ce:<\/strong><br \/>\n        Kompletne okablowanie, z\u0142\u0105czki i elementy monta\u017cowe.\n    <\/div>\n<p>    <!-- INFORMACJA KO\u0143COWA --><\/p>\n<p style=\"        margin:10px 0 0 0;        padding:0;        line-height:1.35;    \"><br \/>\n        Dokumentacja techniczna stanowiska oraz instrukcja obs\u0142ugi<br \/>\n        w j\u0119zyku polskim \u2013 1 kpl.\n    <\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p class=\"has-small-font-size wp-block-paragraph\">Stanowisko edukacyjne przeznaczone do nauki obs\u0142ugi, integracji oraz konfiguracji czujnik\u00f3w z cyfrowym interfejsem komunikacyjnym IO-Link realizowane z wykorzystaniem sterownika PLC oraz panelu operatorskiego HMI. Umo\u017cliwia realizacj\u0119 \u0107wicze\u0144 z zakresu komunikacji sieciowej, zbieranie danych z inteligentnych czujnik\u00f3w, sterowania elementami wykonawczymi i diagnostyki procesu.<\/p>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns5604_9c29bd-80\"><\/div>","protected":false},"featured_media":19775,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[883],"product_tag":[],"class_list":["post-19940","product","type-product","status-publish","has-post-thumbnail","product_cat-stan-eduk","first","instock","taxable","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/sklep.plcexpert.pl\/en\/wp-json\/wp\/v2\/product\/19940","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sklep.plcexpert.pl\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sklep.plcexpert.pl\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sklep.plcexpert.pl\/en\/wp-json\/wp\/v2\/media\/19775"}],"wp:attachment":[{"href":"https:\/\/sklep.plcexpert.pl\/en\/wp-json\/wp\/v2\/media?parent=19940"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/sklep.plcexpert.pl\/en\/wp-json\/wp\/v2\/product_brand?post=19940"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/sklep.plcexpert.pl\/en\/wp-json\/wp\/v2\/product_cat?post=19940"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/sklep.plcexpert.pl\/en\/wp-json\/wp\/v2\/product_tag?post=19940"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}